Ballasted Clarification Technology Provides Low Cost Solution that Meets Phosphorus Limits

CoMag system exceeds performance parameters while providing high-quality effluent

Challenge

Prior to 2007, the Concord, Massachusetts wastewater treatment plant operated under a NPDES permit that allowed a seasonal phosphorus limit of 0.7 mg/L.  However, with the issuance of a new five-year permit with a phosphorus limit of 0.2 mg/L and the probability that future limits could reach as low as 0.05 mg/L, the city of Concord needed a treatment solution that would be reliable and cost-effective over the long term.

 

Solution

​When compared to dissolved air floatation, media filtration and sand ballasted technologies, Concord’s consulting engineers recommended the CoMag® System​ from Evoqua Water Technologies. Key benefits include:

  • Ability to provide effluent TP values from 0.2 mg/L to ≤ 0.05 mg/L simply by adjusting the flocculent dose.

  • Reliability of operation — conventional flocculation and coagulation coupled with high rate clarification and no filters to clog or backwash.

  • Capital cost savings given its small clarifiers and footprint.


The CoMag® System Overview

Simple, reliable and proven, the CoMag® System from Evoqua uses magnetite to ballast conventional chemical floc, enhancing settling rates to dramatically increase the performance of wastewater treatment facilities. Primarily used to improve primary and/or tertiary treatment, the CoMag System easily integrates with planned or existing facilities, making it easier than ever to solve today’s operational and environmental challenges.

At the Concord WWTP, the CoMag System includes six steps:

  • Conventional chemical flocculation with Ferric, Alum or PAC
  • Infusion of the floc with fully inert, finely ground, nonabrasive magnetite
    (Fe3O4) to increase the specific gravity of the floc
  • Coagulation to bind the floc together
  • High rate clarification in traditional but smaller clarifiers
  • Sludge recycled for stable operation, upset prevention and pin floc capture
  • 99+% recycle and reuse of magnetite for low operating costs

Results

Installed in 2007, the CoMag® System exceeded all performance parameters — achieving TP down to 0.2 mg/L, with daily capacity of 1.25 (4.73)/4.4 (16.7) MGD(MLD).



The system now plays an integral role in a larger facility upgrade that includes improvements to the headworks, disinfection system, plant utilities, controls and other processes. Additionally, its high-quality effluent enables the facility to utilize smaller, more cost-effective UV disinfection system.​

Request a Proposal

Contact Evoqua for more information on available solutions

Request a Proposal
靠谱权威风云体育_官方网站-IOS/Android通用版/手机APP下载/最新版 半岛十大真人网_官方网站-IOS/Android通用版/手机APP下载/最新版 E体育十大正规足球_官方网站-IOS/Android通用版/手机APP下载/最新版 风云权威体育充值_官方网站-IOS/Android通用版/手机APP下载/最新版 多福多财怎么玩_官方网站-IOS/Android通用版/手机APP下载/最新版 江南权威最火网_官方网站-IOS/Android通用版/手机APP下载/最新版 知名最新和记体育直营_官方网站-IOS/Android通用版/手机APP下载/最新版 和记体育网络正规网站_官方网站-IOS/Android通用版/手机APP下载/最新版 和记体育信誉知名网站_官方网站-IOS/Android通用版/手机APP下载/最新版 B体育网上最大足球_官方网站-IOS/Android通用版/手机APP下载/最新版